The following error messages may come up on the TNC during data transfer with the HEIDENHAIN
TNC.EXE data transmission program:
DATA CARRIER @: IS FULL
This data carrier cannot receive any additional data because it is full.
FILE NAME NOT PROGRAM NAME
The name of the NC program is not the same as the file name.
INSTRUCTION NOT ALLOWED
The request instruction issued by the control is not allowed.
PROGRAM INCOMPLETE
The NC program does not contain an end block.
PROGRAM NOT PRESENT
The file requested by the control does not exist in the currently configured access path.
PROTECTED FILE
An attempt was made to overwrite a write-protected file or a file with hidden attribute.
SEARCH FEATURE NOT ALLOWED
The search feature is not included in the number of permissible characters.
TRANSFERRED DATA INCORRECT
Four unsuccessful attempts have been made to transmit a block to the control.