Page 296: 1 editing plc-programs

7-6
TNC 416/TNC 406/TNC 306
PLC-functions
3/2000
1.2
PLC — Main menu
TNC 406
PROCESSING TIME
MAXIMUM:
XXX%
CURRENT:
XXX%
TOTAL MEMORY
:
XX KBYTE
VACANT MEMORY
:
XX KBYTE
CODE LENGTH
:
XX KBYTE
Select PLC
editing
mode
Select
tables
M/I/O/T/C
/B/W/D
Select TRACE
mode
Compile PLC
program
Copy from
EPROM to
RAM
Erase PLC
Program
Quit PLC
Mode
TNC 306
ERASE PLC PROGRAM
TRANSFER PROGRAM FROM EPROM
PLC EDITING MODE
PLC PROGRAM TRACE MODE
TABLES M/I/O/C/T/B/W/D
TRANSLATE PLC PROGRAM
UTILIZATION/MEMORY
Select the desired mode with the cursor keys ↑ and ↓ and activate by pressing ENT.
To exit the menu and return to the previous NC mode, press END again.
1.2.1 Editing PLC-programs
In the operating mode PLC EDITING MODE (TNC 406 Soft key EDIT) an instruction list can be edited
via TNC keyboard.
The keys of the TNC 306 assume new assignments, which are indicated on a special tactile
membrane that is place over the TNC keyboard. The tactile membrane is included with this
Technical Manual. Before editing a new program, it is necessary to reserve memory in the
UTILIZATION/ MEMORY mode.
After the ENT key is pressed, the editor identifies itself with
"0
EM"
"0" stands for program line 0 and "EM" for End of Module.
When entering an instruction, "EM" automatically moves downward by one line.
The PLC editing mode can be exited by pressing the END key/ soft key.