List of machine parameters, Measuring systems and machines – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 253

3/2000
TNC 416/TNC 406/TNC 306
List of machine parameters
5-5
3
List of machine parameters
3.1 Measuring systems and machines
Machine
parameter
Function and input
Change
via
Reaction
Page
MP10
Active axes
Entry range:
1 to 15 (TNC 306)
% xxxxx (TNC 416/406)
Bit 0
X axis
+0 = Not active
+1 = Active
Bit 1
Y axis
+0 = Not active
+2 = Active
Bit 2
Z axis
+0 = Not active
+4 = Active
Bit 3
4th axis +0 = Not active
+8 = Active
Bit 4
*
5th axis +0 = Not active
+16 = Active
RESET
4-5
MP31
Amplitude monitoring of the measuring
system signals
Entry range:
1 to 15 (TNC 306)
% xxxxx (TNC 416/406)
X
+0 = Monitoring not active
+1 = Monitoring active
Y
+0 = Monitoring not active
+2 = Monitoring active
Z
+0 = Monitoring not active
+4 = Monitoring active
IV
+0 = Monitoring not active
+8 = Monitoring active
V *
+0 = Monitoring not active
+16 = Monitoring active
RESET
4-8
MP32
Frequency monitoring
Entry range:
1 to 15 (TNC 306)
% xxxxx (TNC 416/406)
X
+0 = Monitoring not active
+1 = Monitoring active
Y
+0 = Monitoring not active
+2 = Monitoring active
Z
+0 = Monitoring not active
+4 = Monitoring active
IV
+0 = Monitoring not active
+8 = Monitoring active
V *
+0 = Monitoring not active
+16 = Monitoring active
RESET
4-9
*
only TNC 416/406