2 eroding parameters in erosion tables – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 163

3/97
TNC 406/TNC 306
4 Gap control
4-63
4.7.1 Eroding parameters as Q-parameters in the NC program
If machine parameter MP2199 = 0 (erosion tables not active), Q-parameters Q90 to Q99 are
reserved for the storage of eroding parameters and are transferred to the PLC doublewords D668 to
D704 accordingly.
D668
Q-parameter
Q90 (NC
→ PLC)
D672
Q-parameter
Q91
D676
Q-parameter
Q92
D680
Q-parameter
Q93
D684
Q-parameter
Q94
D688
Q-parameter
Q95
D692
Q-parameter
Q96
D696
Q-parameter
Q97
D700
Q-parameter
Q98
D704
Q-parameter
Q99
4.7.2 Eroding parameters in erosion tables
If machine parameter MP2199 = 2 (erosion tables active), the eroding parameters are stored in the
form of erosion tables and transferred to the PLC addresses as defined below. Furthermore, Q-
parameters (Q96–Q98) are also used for NC to PLC transfers.
D412
Q-parameter
Q96 (NC
→ PLC)
D416
Q-parameter
Q97
D420
Q-parameter
Q98
B666
Maximum power stage
B667
Minimum power stage
B668
Power stage number
NR
1)
(.E - table
→ PLC) can be changed during
machining via Q-parameter Q99
B669
Low voltage current
LV
2)
B670
High voltage current
HV
2)
B671
Nominal gap voltage
GV
2)
2) These eroding parameters can be
W672
Pulse on duration
TON
2)
temporarily changed during machining
B674
Pulse off duration
TOF
2)
via the screen status display
B675
Servo sensitivity
SV
2)
(.E - table
→ NC)
W676
Auto Jump Distance
AJD
2)
(.E - table
→ PLC)
W678
Erosion Time
ET
2)
B680
Arc sensitivity
AR
B681
Polarity electrode
P
W682
High voltage selector
HS
W684
Wear rate
WR
W686
Surface finishing
RA
D688
Stock removal
SR
W692
Two-times gap
2G
W694
Minimum undersize
UNS
B696
Auxiliary parameter 1
AUX1
B697
Auxiliary parameter 2
AUX2
B698
Auxiliary parameter 3
AUX3
B699
Auxiliary parameter 4
AUX4