![background image](https://www.manualsdir.com/files/815307/content/doc169.png)
3/97
TNC 406/TNC 306
4 Gap control
4-69
Example: Read 8 Markers:
Eight Markers are to be read starting from Marker M1800.
Marker states: 0 0 0 1 1 1 1 0
Generator protocol:
n > Generator transmits: CA 03 00 07 08 0C PLC transmits: ACK or NAK PLC protocol: n > <00..FF> PLC transmits: CA 04 00 07 08 1E 14 Generator transmits: ACK or NAK Example: Reset a Marker Marker 1800 is to be reset. Generator protocol: n > <00..FF> Generator transmits: CA 04 02 07 08 00 09 PLC transmits: ACK or NAK Example: Read Bytes Five bytes are to be read starting with Byte 22 (B22=1F, B23=07, B24= 2A, B25=11, B26=00). Generator protocol: n > Generator transmits: CA 04 04 00 16 05 13 PLC transmits: ACK or NAK PLC protocol: n > PLC transmits: CA 08 04 00 16 1F 07 2A 11 00 3B Generator transmits: ACK or NAK Example: Load Bytes Three bytes (B100, B101 and B102) are to be loaded into the 3 bytes starting with B22. Generator protocol: n > Generator transmits: CA 06 06 00 16 64 65 66 71 PLC transmits: ACK or NAK