TNC 416/TNC 406/TNC 306
List of machine parameters
5-7
Machine
parameter
Function and input
Change
via
Reaction
Page
MP115.0
Position encoder inputs 1V
PP
or 11µA
Input: %xxxxx
0 = 1 V
PP
1 = 11µA
New MP in TNC 416 software 286 180-01
RESET
-
MP115.1
Reserved
Input: %00000
New MP in TNC 416 software 286 180-01
MP115.2
Input frequency of position encoders
Input: %xxxxx
0 = 50kHz for 1V
PP
; 50kHz for 11µA
1 = 350kHz for 1V
PP
; 150kHz for 11µA
New MP in TNC 416 software 286 180-01
RESET
-
MP 120.0-4
Assignment of the analog outputs
Entry range: 0 to 4
0 = Analog output 1
1 = Analog output 2
2 = Analog output 3
3 = Analog output 4
4 = Analog output 5 *
RESET
4-12
MP210
Counting direction of the encoder signals
Entry range:
0 to 31 (TNC 306)
% xxxxx (TNC 416/406)
Bit 0
X axis
+0 = Positive
+1 = Negative
Bit 1
Y axis
+0 = Positive
+2 = Negative
Bit 2
Z axis
+0 = Positive
+4 = Negative
Bit 3
4th axis +0 = Positive
+8 = Negative
Bit 4 *
5th axis +0 = Positive
+16 = Negative
RESET
4-7
MP330.0-4
Grating period
Entry range: 1 to 360 [µm] or [1/1000
°]
MP330.0
X axis
MP330.1
Y axis
MP330.2
Z axis
MP330.3
4th axis
MP330.4
5th axis
Canceled in TNC 416 software 286 180-01
Canceled in TNC 406 software 280 620-08
4-6