Adaptation of the data interface, 6 adaptation of the data interface – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 266

5-18
TNC 416/TNC 406/TNC 306
List of machine parameters
3/2000
3.6 Adaptation of the data interface
Machine
parameter
Function and input
Change
via
Reaction
Page
MP5010
EXT mode:
ASCII character for end of data
Entry range: 0 to 127
123
8-26
MP5011
EXT mode:
ASCII character for end of transmission
Entry range: 0 to 127
123
8-26
MP5020
EXT mode: interface configuration
Bit 0
Seven or eight data bits
+0 = 7 data bits
+1 = 8 data bits
Bit 1
No function
Bit 2
Transmission stop via RTS
+0 = inactive
+4 = active
Bit 3
Transmission stop via DC3
+0 = inactive
+8 = active
Bit 4
Character parity even or odd
+0 = even
+16 = odd
Bit 5
Character parity required
+0 = not required
+32 = required
Bit 6
No function
Bit 7
Number of stop bits
+0
= 2 stop bits
+128
= 1 stop bit
123
8-27
MP5100
Parity Bit for LSV2-Protocol
Entry value: 0 to 2
0 = no parity
1 = even parity
2 = odd parity
–
MP5200
Baud rate for RS-422 interface of the
0 = baud rate 9600
1 = baud rate 38400
–
MP5990
Check block number sequence with external data
transfer
Entry value: 0 or 1
0 = Check block number sequence
1 = No check
123
8-26