HEIDENHAIN TNC 306 Technical Manual User Manual
Page 264

5-16
TNC 416/TNC 406/TNC 306
List of machine parameters
3/2000
Machine
parameter
Function and input
Change
via
Reaction
Page
MP2120
Arc detection
(electrode retraction time)
Entry range: 1 to 99.9 [s]
123
4-60
MP2130
Maximum speed for feed forward control during
erosion
Entry range: 0 to 500 [mm/min]
4-56
MP2131
Feed rate limit to switch to new eroding feed rate
from MP 2132
Entry range: 0 to 500 [mm/min]
4-57
MP2132
New eroding feed rate when value from MP 2131
exceeded
Entry range: 0 to 500 [mm/min]
4-57
MP2133
Retraction speed during short circuit detected at
connector X12
Entry range: 0 to 500 [mm/min]
4-59
MP2141
Free-run feed rate if analog input is greater than
threshold from W520 (MP2081)
Entry range: 0 to 3000 [mm/min]
–
MP2142
Erosion feed rate (MP2081=1)
Forward: F = MP2142 * SV [%]
Backward: F = MP2142 * SV [%] * W522 [Factor]
Entry range: 0 to 3000 [mm/min]
–
MP2190
Constant-speed positioning during flushing
Entry values: 0, 1, 2
0 =
Electrode braked between each block
1 =
If the path is geometrically continuous,
the electrode moves at constant speed
2 =
Electrode moves at constant speed even
if the path is non-continuous
Removed in TNC 406 as of software 280 620-07
123
–
MP2199
Erosion table on/off
Entry values: 0 or 2
0 =
Tables not active
2 =
Tables active
4-62