beautypg.com

Integral plc, 5 integral plc – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 265

background image


3/2000

TNC 416/TNC 406/TNC 306

List of machine parameters

5-17

3.5 Integral PLC

Machine
parameter

Function and input

Change
via

Reaction

Page

MP4010

PLC program from RAM or from EPROM
Entry value: 0 or 1

0 =

EPROM

1 =

RAM

7-21

MP4020

Erosion parameter table from RAM or from
EPROM
Entry value: 0 or 1
0 =

EPROM

1 =

RAM

4-64

MP4030

Switchover of the PLC interface from marker
area to word area
Input value: 0 or 1
0 =

marker range active (M2000 to M2548)

1 = word range active (W1024 to W1060)"
New MP in TNC 416 software 286 180-04
New MP in TNC 406 software 280 620-10

-

MP4060.0-4

Path-dependent lubrication
Entry range: 0 to 65 535 (in units of 65 536 µm)

4-16

MP4110.0-47

PLC: programmed duration for timers 0–47
Entry range: 0 to 65 535 (in units of

40 ms)20/40 ms, depending of MP1700)

7-17

MP4120.0-31

PLC: counter preset value for counters 0–31
Entry range: 0 to 65 535 in units of 40 ms
(TNC 406: 20 or 40 ms depending on MP 1700)

7-19

MP4210.0-47

PLC: 48 positioning values for PLC positioning or
datum shift
Entry range: –30.000 to +30.000 [mm]

7-16

MP4220.0-7

Setting a number in the PLC (W960 ... W974)
Entry range: 0 to 65 535

7-16

MP4310.0-15

Setting a number in the PLC (W976 ... W1006)
Entry range: 0 to 65 535

7-16

MP4320.0-7

Setting a number in the PLC (W1008 ... W1022)
Entry range: 0 to 65 535

7-16