Integral plc, 5 integral plc – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 265

3/2000
TNC 416/TNC 406/TNC 306
List of machine parameters
5-17
3.5 Integral PLC
Machine
parameter
Function and input
Change
via
Reaction
Page
MP4010
PLC program from RAM or from EPROM
Entry value: 0 or 1
0 =
EPROM
1 =
RAM
7-21
MP4020
Erosion parameter table from RAM or from
EPROM
Entry value: 0 or 1
0 =
EPROM
1 =
RAM
4-64
MP4030
Switchover of the PLC interface from marker
area to word area
Input value: 0 or 1
0 =
marker range active (M2000 to M2548)
1 = word range active (W1024 to W1060)"
New MP in TNC 416 software 286 180-04
New MP in TNC 406 software 280 620-10
-
MP4060.0-4
Path-dependent lubrication
Entry range: 0 to 65 535 (in units of 65 536 µm)
4-16
MP4110.0-47
PLC: programmed duration for timers 0–47
Entry range: 0 to 65 535 (in units of
40 ms)20/40 ms, depending of MP1700)
7-17
MP4120.0-31
PLC: counter preset value for counters 0–31
Entry range: 0 to 65 535 in units of 40 ms
(TNC 406: 20 or 40 ms depending on MP 1700)
7-19
MP4210.0-47
PLC: 48 positioning values for PLC positioning or
datum shift
Entry range: –30.000 to +30.000 [mm]
7-16
MP4220.0-7
Setting a number in the PLC (W960 ... W974)
Entry range: 0 to 65 535
7-16
MP4310.0-15
Setting a number in the PLC (W976 ... W1006)
Entry range: 0 to 65 535
7-16
MP4320.0-7
Setting a number in the PLC (W1008 ... W1022)
Entry range: 0 to 65 535
7-16