Positioning, 2 positioning – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 259

3/2000
TNC 416/TNC 406/TNC 306
List of machine parameters
5-11
3.2 Positioning
Machine
parameter
Function and input
Change
via
Reaction
Page
MP1010.0–4 Rapid traverse
Entry range, linear axis:
80 to 30 000 [mm/min]
Entry range, rotary axis:
80 to 30 000 [°/min]
4–42
MP1020.0–4 Manual feed
Entry range, linear axis:
80 to 30 000 [mm/min]
Entry range, rotary axis:
80 to 30 000 [°/min]
4–43
MP1030.0–4 Positioning window
Entry range, linear axis:
0.001 to 2.000 [mm]
Entry range, rotary axis:
0.001 to 2.000 [°]
4–48
MP1040
Polarity of the nominal value voltage for positive
traverse direction
Entry range: 0 to 15 (TNC 306)
% xxxxx (TNC 416/406)
Bit 0
X axis
+0 = Positive
+1 = Negative
Bit 1
Y axis
+0 = Positive
+2 = Negative
Bit 2
Z axis
+0 = Positive
+4 = Negative
Bit 3
4
th
axis
+0 = Positive
+8 = Negative
Bit 4 *
5
th
axis
+0 = Positive
+16 = Negative
4–7
MP1050.0–4 Analog voltage for rapid traverse
Entry range: +4.5 to +9 [V]
4–42
MP1060.0–4 Acceleration
Entry range: 0.001 to 9.0 [m/s
2
]
4–41
MP1070
Radial acceleration
Entry range: 0.001 to 3.0 [m/s
2
]
4–45
MP1090
Default feed rate during positioning
Entry range: 0 to 30 000 [mm/min]
123
4–60
MP1092
MP1093
MP1094
MP1095
MP1096
MP1097
Circular feed rates in the disk cycle (marker M2640)
Entry range: 0 to 30 000 [mm/min]
Modes 0 and 4 (erosion, M2640=0)
Modes 0 and 4 (spark–out, M2640=1)
Modes 1 and 5 (erosion, M2640=0)
Modes 1 and 5 (spark–out, M2640=1)
Modes 2/3 and 6/7 (erosion, M2640=0)
Modes 2/3 and 6/7 (spark–out, M2640=1)
123
4–88