LE 416

X1, X2, X3, X4 and X6 Encoder (1 V

PP

/11µA)

Logic unit

Encoder cable

D-sub
terminal
(male) 15-pin

Assignment
1 V

PP

Assignment
11µA

D-sub
connector
(female) 15-
pin

1 V

PP

11µA

1

+ 5 V (U

P

)

+ 5 V

1

Brown/Green

Brown

2

0 V (U

N

)

0 V

2

White/Green

White

3

A+

I

1

+

3

Brown

Green

4

A–

I

1

4

Green

Yellow

5

0 V

0 V

5

White/Brown
(internal shield)

6

B+

I

2

+

6

Gray

Blue

7

B–

I

2

7

Pink

Red

8

0 V

0 V

8

9

+ 5 V

+ 5 V

9

Blue

10

R+

I

0

+

10

Red

Gray

11

0 V

0 V

11

White

12

R–

I

0

12

Black

Pink

13

0 V

0 V

13

14

Do not use

Do not use

14

Violet

15

Do not use

Do not use

15

Housing

External
shield

External shield Housing

External shield

External shield