beautypg.com

HEIDENHAIN TNC 306 Technical Manual User Manual

Page 288

background image


3/2000

TNC416/TNC 406/TNC 306

List of Bytes, Words and Double Words

6–11

Word

Function

Transmission

Page

W584

Axis error compensation, axis 5

PLC → NC

4-22

W586

Nominal value output on analog output 6 (default value 500 =
5,0 Volt) (TNC 406 as of software 280 62x-08)

PLC → NC

W588

MP2010.0 (100...10000)

W590

MP2010.1 (100...10000)

W592

MP2020.0 (100...10000)

W594

MP2020.1 (100...10000)

B596

MP2030.0 (0...100%)

B597

MP2030.1 (0...100%)

B600

Identifier: 1=EL CALL; 2=WP CALL

NC → PLC

B601....
.B603

Vacant

NC → PLC

B604...
B619

16-byte ASCII string EL name or WP name

NC → PLC

B620....
B623

Vacant

NC → PLC

B624....
B627

Vacant

PLC → NC

D628
D632
D636
D640
D644
D648

Identifier 1, EL CALL
Compensation in X
Compensation in Y
Compensation in Z
Compensation in C
Undersize
Radius

Identifier 2, WP CALL
Shift in X
Shift in Y
Shift in Z
Rotation in C

PLC → NC

B666

LS max cycle generator (Q150)

NC → PLC

B667

LS min cycle generator (Q151)

NC → PLC

B668

Power stage number

NR*

E-table → PLC 4-63

B669

Low voltage current

LV*

E-table → PLC 4-63

B670

High voltage current

HV*

E-table → PLC 4-63

B671

Gap voltage

GV*

E-table → PLC 4-63

W672

Pulse ON duration

TON*

E-table → PLC 4-63

B674

Pulse OFF duration

TOF*

E-table → PLC 4-63

B675

Servo sensitivity

SV*

E-table → NC

4-63

W676

Auto jump distance

AJD*

E-table → PLC 4-63

W678

Erosion time

ET*

E-table → PLC 4-63

B680

Arc sensitivity

AR*

E-table → PLC 4-63

B681

Polarity electrode 0="+", 1="–"

P*

E-table → PLC 4-63

W682

High voltage selector

HS*

E-table → PLC 4-63

W684

Wear rate [%]

WR*

E-table → PLC 4-63

W686

Surface finish

RA*

E-table → PLC 4-63

D688

Stock removal

SR*

E-table → PLC 4-63

This manual is related to the following products: