HEIDENHAIN TNC 306 Technical Manual User Manual
Page 50

3/99
TNC 416/TNC 406/TNC 306
Nominal value output / Gap signal input 3–35
Suggested solution for connecting and wiring the shielding in the connection box:
Insulated against housing
Leads are provided
with end sleeves.
Cable screens are led onto 0.14 mm
2
insulated strands via crimp eyelets.
SERVO
1 2 3 4 5 6 7 8 9 1 0 11 12 13 14 15 16
LE
•
•
X
Y
Z
S
IV
GAP
Pin number
Assignment
1
Analog output
X-axis
2
Analog output 0V
X-axis
3
Analog output
Y-axis
4
Analog output 0V
Y-axis
5
Analog output
Z-axis
6
Analog output 0V
Z-axis
7
Analog output
IVth axis
8
Analog output 0V
IVth axis
11
Analog input
Gap signal
12
Analog input 0V
Gap signal
13
Screen connection
14
Screen connection
15
Screen connection
16
Screen connection
This manual is related to the following products: