background image


3/99

TNC 416/TNC 406/TNC 306

Nominal value output / Gap signal input 3–35

Suggested solution for connecting and wiring the shielding in the connection box:

Insulated against housing

Leads are provided
with end sleeves.

Cable screens are led onto 0.14 mm

2

insulated strands via crimp eyelets.

SERVO

1 2 3 4 5 6 7 8 9 1 0 11 12 13 14 15 16

LE

X

Y

Z

S

IV

GAP

Pin number

Assignment

1

Analog output

X-axis

2

Analog output 0V

X-axis

3

Analog output

Y-axis

4

Analog output 0V

Y-axis

5

Analog output

Z-axis

6

Analog output 0V

Z-axis

7

Analog output

IVth axis

8

Analog output 0V

IVth axis

11

Analog input

Gap signal

12

Analog input 0V

Gap signal

13

Screen connection

14

Screen connection

15

Screen connection

16

Screen connection

This manual is related to the following products: