beautypg.com

HEIDENHAIN TNC 306 Technical Manual User Manual

Page 438

background image


3/97

TNC 406/TNC 306

2 TNC data interfaces

8-25

Stop bits
Bit 7 determines the number of stop bits sent at the end of a character.

MP 5020

EXT mode: Data format and transmission stop
Input range: 0 to 189

Bit 07 or 8 data bits

+0 = 7 data bits
+1 = 8 data bits

Bit 1No function
Bit 2Transmission stop by RTS

+0 = not active
+4 = active

Bit 3Transmission stop by DC3

+0 = not active
+8 = active

Bit 4Character parity

+0 = even
+16 = uneven

Bit 5Character parity

+0 = not desired
+ 32 = desired

Bit 6No function
Bit 7Stop bits

+0 =

2 stop bits

+128 = 1 stop bit

This manual is related to the following products: