beautypg.com

HEIDENHAIN TNC 306 Technical Manual User Manual

Page 256

background image


5-8

TNC 416/TNC 406/TNC 306

List of machine parameters

3/2000

Machine
parameter

Function and input

Change
via

Reaction

Page

MP331.0-4

Distance per number of signal periods out of
MP332
Input: 0.001 to 99 999.999

[mm or °]

New MP in TNC 416 software 286 180-01
New MP in TNC 406 software 280 620-08

Reset

MP332.0-4

Number of signal periods in the distance from
MP331
Input: 1 to 16 777 215

New MP in TNC 416 software 286 180-01
New MP in TNC 406 software 280 620-08

Reset

MP334.0-4

Distance between reference marks for encoders
with distance-coded reference marks
Input:

0 to 65535 [grating periods]

0=1000 grating periods
(standard setting)

New MP in TNC 416 software 286 180-01
New MP in TNC 406 software 280 620-08

Reset

MP410

Designation of axis 4
Entry value: 0 to 2

0 = A
1 = B
2 = C

RESET

4-11

MP411 *

Designation of axis 5
Entry value: 0 to 5

0 = A
1 = B
2 = C
3 = U
4 = V
5 = W

4-11

MP720.0-4

Correction factor for linear compensation
Entry range: –1.000 to +1.000 [mm/m]
MP720.0

X axis

MP720.1

Y axis

MP720.2

Z axis

MP720.3

4th axis

MP720.4 *

5th axis

4-18

MP710

Backlash compensation for axis 4
Input: –1.000 to +1.000 [mm] or

[°]

-

MP711

Backlash compensation for axis 5
Input: –1.000 to +1.000 [mm] or

[°]

-

This manual is related to the following products: