beautypg.com

HEIDENHAIN TNC 306 Technical Manual User Manual

Page 260

background image


5-12

TNC 416/TNC 406/TNC 306

List of machine parameters

3/2000

Machine
parameter

Function and input

Change
via

Reaction

Page

MP1110

Standstill monitoring (Error D)
Entry range: 0.001 to 30 [mm]

4–48

MP1140

Movement monitoring (Error C)
Entry range: 0.03 to 10 [V]

4–47

MP1141

Maximum voltage difference between two control
loop cycles (Error F)
Entry range: 0.03 to 10 [V]

Removed in TNC 406 as of software version
280 620-07, because the acceleration monitoring
is now automatic.

4–47

MP 1220

Automatic drive offset adjustment
Entry range: 0 to 65 535 [s]

0 = No automatic adjustment

4–44

MP1320

Traverse direction when approaching the
reference marks
Entry range: 0 to 15(TNC 306)

% xxxxx (TNC 416/406)

Bit 0

X axis

+0 = Positive
+1 = Negative

Bit 1

Y axis

+0 = Positive
+2 = Negative

Bit 2

Z axis

+0 = Positive
+4 = Negative

Bit 3

4

th

axis

+0 = Positive
+8 = Negative

Bit 4 *

5

th

axis

+0 = Positive
+16 = Negative

4–33

MP1330.0–4 Feed rate for crossing the reference marks

Entry range: 80 to 30 000 [mm/min]

4–33

MP1331.0–4 Feed rate when leaving reference end position

(only for encoders with one reference mark,
MP1350 = 1)

Entry range: 80 to 500 [mm/min]

4–33

MP1340.0–4 Axis sequence for crossing the reference marks

Entry range: 0 to 5

0 = No reference mark evaluation
1 = X axis first
2 = Y axis first
3 = Z axis first
4 = 4

th

axis first

5 = 5

th

axis first *

4–33

• only TNC 416/406

This manual is related to the following products: