HEIDENHAIN TNC 306 Technical Manual User Manual
Page 260
![background image](https://www.manualsdir.com/files/815307/content/doc260.png)
5-12
TNC 416/TNC 406/TNC 306
List of machine parameters
3/2000
Machine
parameter
Function and input
Change
via
Reaction
Page
MP1110
Standstill monitoring (Error D)
Entry range: 0.001 to 30 [mm]
4–48
MP1140
Movement monitoring (Error C)
Entry range: 0.03 to 10 [V]
4–47
MP1141
Maximum voltage difference between two control
loop cycles (Error F)
Entry range: 0.03 to 10 [V]
Removed in TNC 406 as of software version
280 620-07, because the acceleration monitoring
is now automatic.
4–47
MP 1220
Automatic drive offset adjustment
Entry range: 0 to 65 535 [s]
0 = No automatic adjustment
4–44
MP1320
Traverse direction when approaching the
reference marks
Entry range: 0 to 15(TNC 306)
% xxxxx (TNC 416/406)
Bit 0
X axis
+0 = Positive
+1 = Negative
Bit 1
Y axis
+0 = Positive
+2 = Negative
Bit 2
Z axis
+0 = Positive
+4 = Negative
Bit 3
4
th
axis
+0 = Positive
+8 = Negative
Bit 4 *
5
th
axis
+0 = Positive
+16 = Negative
4–33
MP1330.0–4 Feed rate for crossing the reference marks
Entry range: 80 to 30 000 [mm/min]
4–33
MP1331.0–4 Feed rate when leaving reference end position
(only for encoders with one reference mark,
MP1350 = 1)
Entry range: 80 to 500 [mm/min]
4–33
MP1340.0–4 Axis sequence for crossing the reference marks
Entry range: 0 to 5
0 = No reference mark evaluation
1 = X axis first
2 = Y axis first
3 = Z axis first
4 = 4
th
axis first
5 = 5
th
axis first *
4–33
• only TNC 416/406