4-6

TNC 406/TNC 306

1 Machine axes

3/97

The TNC always does a 4-fold evaluation of the signals at the square-wave inputs.

If a counting step of < 1

µm or 0.001° is desired, the signal period (

) must not be greater

than 4

µm or 0.004°.

Angular measurement : the signal period of angle encoders is calculated as follows:

Signal period (~) =

360°

line count

· 1000

or

Signal period (

) =

360°

line count

·

1

interpolation factor

· 1000

If angular measurement is made by gearing up or down, this must be taken into account when
calculating the signal period.

MP330

Signal period

Entry range 1 to 360 in [

µm] or

[

1000

]

MP330.0

X axis

MP330.1

Y axis

MP330.2

Z axis

MP330.3

Axis 4

MP330.4 *

Axis 5

*

only TNC 406