HEIDENHAIN TNC 306 Technical Manual User Manual
Page 106

4-6
TNC 406/TNC 306
1 Machine axes
3/97
The TNC always does a 4-fold evaluation of the signals at the square-wave inputs.
If a counting step of < 1
µm or 0.001° is desired, the signal period (
) must not be greater
than 4
µm or 0.004°.
Angular measurement : the signal period of angle encoders is calculated as follows:
Signal period (~) =
360°
line count
· 1000
or
Signal period (
) =
360°
line count
·
1
interpolation factor
· 1000
If angular measurement is made by gearing up or down, this must be taken into account when
calculating the signal period.
MP330
Signal period
Entry range 1 to 360 in [
µm] or
[
1°
1000
]
MP330.0
X axis
MP330.1
Y axis
MP330.2
Z axis
MP330.3
Axis 4
MP330.4 *
Axis 5
*
only TNC 406