HEIDENHAIN TNC 306 Technical Manual User Manual
Page 29

3–14
TNC 416/TNC 406/TNC 306
Overview of connections
3/99
LE 406
X1
X2
X3
X4
X5
X6
X12
X8
X21
X22
X23
B
X43
X47
X42 X46
X41 X45
X44
24V
X31
X1
Measuring system 1 (11µA)
X2
Measuring system 2 (11µA)
X3
Measuring system 3 (11µA)
X4
Measuring system 4 (11µA)
X5
Measuring system 5 (
)
X6
Measuring system 6 (
)
X8
Nominal value outputs 1,2,3,4,5
gap signal input
X12
Touch probe system;
Short-circuit signal input
X21
Data interface RS-232-C/V.24
X22
Data interface RS-422/V.11
X23
Electronic handwheel HR 130/HR 410
X41
PLC output
X42
PLC input
X43
VDU BC 110
X45
TNC keyboard TE 400
X46
Machine operating panel
X47
PLC I/O board PL 410 B
X31
Power supply 24 V for NC
X44
Power supply 24 V for PLC
B
Signal ground
Interfaces X1, X2, X3, X4, X5, X6, X8, X12, X21, X22, X23, X41, X42, X43, X45, X46 and X47
comply with the recommendations in VDE 0160, 5. 88 for separation from line power.
Danger to internal components!
Do not engage or disengage any connections while the unit is under power.
The outputs at connection X.... (indicate pin number if appropriate) are metallically isolated
from the device electronics by means of optocouplers.