2 signal levels, 3 signal designation – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 424

background image


3/97

TNC 406/TNC 306

2 TNC data interfaces

8-11

2.2.2 Signal levels

The RS-232-C interface must differentiate between two different signal lines and their levels.

Data lines:
The data signals are defined as being logic "1" (MARK) over the range –3V to –15V and as logical "0"
(SPACE) over the range +3V to +15V.

Control and signal lines:
These signals are defined as being ON (High) over the range +3V to +15V and as OFF (Low) over the
range from –3V to –15V.

For all of the signals, the voltage range from –3V to +3V is not defined as a logic level and can
therefore not be evaluated.

1

3

U [V]

+ 15

– 15

+

1

3

Datensignale

Data signals

Steuer- und Meldesignal

Control and message signal

"0"

SPACE

HIGH

ON

"1"

MARK

LOW

OFF

0

2.2.3 Signal designation

The RS-232-C interface distinguishes between data lines, control/signal lines and the earth
conductor.

Data lines:

TxD

Transmitted data

RxD

Received data