beautypg.com

HEIDENHAIN TNC 306 Technical Manual User Manual

Page 243

background image


2/97

TNC 406/TNC 306

15 Commissioning and start-up procedure

4-143

No

No

Yes

No

Yes

No

No

Yes

Yes

Start reference

traverse with

axis direction keys

?

(Both types of
referencing must
be performed!)

Axis traverse

direction correct?

(defined in MP1040

and MP210)

"Cross positioning error"

or incorrect

traverse direction

after passing over

ref. marks?

Line voltage on

START

Erase POWER INTERRUPTED error message with CE

Control voltage on;
axes are in the control loop

Gross

positioning error

(MP1040 or

MP210 incorrect)

?

Traverse

direction correct?

(as defined

in MP1320)

Line
voltage
off

Change
MP210
MP1040
MP1320

Reference traverse with
machine START button

Test the traverse direction of
referencing in each axis

Test the traverse direction
in each axis

This flow diagram must be worked through for every axis!