4-14

TNC 406/TNC 306

1 Machine axes

3/97

Software limit switch range 3
Activated by PLC: M2817 = 1, M2816 = 0

MP912.0

Software limit switch X+

MP912.1

Software limit switch Y+

MP912.2

Software limit switch Z+

MP912.3

Software limit switch 4+

MP912.4 *

Software limit switch 5+

MP922.0

Software limit switch X–

MP922.1

Software limit switch Y–

MP922.2

Software limit switch Z–

MP922.3

Software limit switch 4–

MP922.4 *

Software limit switch 5–

The markers M2816 and M2817 are used to define the software limit switch range.

M2816

M2817

Software limit switch range

0

0

Range 1 (MP910.X; MP920.X)

1

0

Range 2 (MP911.X; MP921.X)

0

1

Range 3 (MP912.X; MP922.X)

The change-over to the selected software limit switch range must be activated by the strobe-marker
M2824 by the PLC. This strobe-marker is reset by the NC after the change-over has been carried
out.

Set

Reset

M2824

Activation of the software limit switch ranges

PLC

NC

If one of the software limit switches is reached, the error message "LIMIT SWITCH ..." appears and
the appropriate marker (M2624 to M2633) is set.

Marker

Function

Set

Reset

M2624

Limit switch X+

NC

NC

M2625

Limit switch X–

M2626

Limit switch Y+

M2627

Limit switch Y–

M2628

Limit switch Z+

M2629

Limit switch Z–

M2630

Limit switch 4+

M2631

Limit switch 4–

M2632*

Limit switch 5+

M2633*

Limit switch 5–

* 0nly TNC 406