Normally, when an M-function is produced, the program run in the operating modes "Program
run/full sequence" and "Program run/single block" is interrupted until the PLC acknowledges that the
M-function has been performed.
In some applications the program should be executed continuously and not wait for the
acknowledgment of the M-function. This function can be selected by machine parameter MP7440,
Bit 2.
If this function is selected then PLC-positioning, datum-correction, or limit switch range-change are
all not permitted during the output of the M-function.