beautypg.com

2 current tool axis, 3 vdu, Display – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 112: 3 vdu display

background image


4-12

TNC 406/TNC 306

1 Machine axes

3/97

MP120

Assignment of the analog outputs

Entry:

0 = output 1
1 = output 2
2 = output 3
3 = output 4
4 = output 5 *

MP120.0 X

axis

MP120.1 Y

axis

MP120.2 Z

axis

MP120.3 Axis

4

MP110.4 *

Axis 5

1.2.2 Current tool axis

In the NC-block "TOOL CALL" it is determined whether the tool moves parallel to one of the principle
axes X, Y, Z or to the fourth axis. The markers M2100 to M2103 are used to show which of the four
axes is currently defined as the tool axis. The appropriate marker is then set.

Set

Reset

M2100

X-axis is tool axis

NC

NC

M2101

Y-axis is tool axis

M2102

Z-axis is tool axis

M2103

Axis 4 is tool axis

1.3 VDU display

Machine parameters can be used to select which of the active axes (MP10) should be displayed in
the status window.

MP40 VDU

display

Entry range: 1 to 31

Bit 0

X axis

+0 = not active
+1 = active

Bit 1

Y axis

+0 = not active
+2 = active

Bit 2

Z axis

+0 = not active
+4 = active

Bit 3

Axis 4

+0 = not active
+8 = active

Bit 4 *

Axis 5

+0 = positive
+16 = negative

*

only TNC 406