beautypg.com

Nc power supply, 1 nc power supply – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 33

background image


3–18

TNC 416/TNC 406/TNC 306

Power supply

3/99

4.1.1 NC power supply

LE 416

Terminal
X31

Assignment

Protective ground (YL/GN)

U

1

Phase 1

330 Vac to 450 Vac;

U

2

Phase 2

50 to 60 Hz

–U

Z

Do not use

+U

Z

Do not use

LE 406/LE 306

Pin number
X 31

Assignment

1

+ 24 V DC

2

0 V

The NC section of the LE must not be supplied
from the control voltage of the machine. It
requires its individual, external and separately
generated supply voltage according to
VDE 0551. Use 24 V DC with a permissible AC
component of 1.5 Vpp (recommended filter
capacitor 10 000 µF/40 V DC).

24 V

U

t

1.5 V

pp

This manual is related to the following products: