beautypg.com

User-parameters, 8 user-parameters – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 188

background image


4-88

TNC 406/TNC 306

6 Display and operation 4

3/97

MP1092

to

MP1097

Circular feed rates in the disk cycle
(if marker M2640 is set)
Entry range: 0 to 30 000 [mm/min]

MP1092

Modes: 0 and 4 (erosion, M2640=0)

MP1093

Modes: 0 and 4 (spark-out, M2640=1)

MP1094

Modes: 1 and 5 (erosion, M2640=0)

MP1095

Modes: 1 and 5 (spark-out, M2640=1)

MP1096

Modes: 2/3 and 6/7 (erosion, M2640=0)

MP1097

Modes: 2/3 and 6/7 (spark-out, M2640=1)

Set

Reset

M2616

Free run during erosion or spark-out is completed

PLC

PLC

M2640

Selects the circular feed rate in the disk cycle

PLC

PLC

M2783

End of eroding path reached (WTG = 0)

NC

NC

M2787

Disk erosion in the last circle

NC

NC

M2620

Feed rate from MP2060 becomes active

PLC

PLC

M2790

Disk erosion completed (MOD 0 to 3)

NC

PLC

M2791

Disk erosion completed (MOD 4 to 7)

NC

PLC

W394

Actual angle while disk cycle

NC

NC

6.8 User-parameters

With the MOD-function up to 16 different machine parameters can be made accessible to the
machine operator as User-parameters.
The machine manufacturer determines in machine parameter MP7330.x which machine parameters
are to be defined as User-parameters.
The dialogs for the user-parameters are defined in the PLC dialogs.

MP7330

Determination of user parameters accessible via MOD function
Entry range: 0 to 9999.00 (No. of the desired machine parameter).

MP7330.0

User-parameter 0

MP7330.1

User-parameter 1

.

.

.

.

MP7330.14

User-parameter 14

MP7330.15

User-parameter 15

This manual is related to the following products: