User-parameters, 8 user-parameters – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 188
![background image](https://www.manualsdir.com/files/815307/content/doc188.png)
4-88
TNC 406/TNC 306
6 Display and operation 4
3/97
MP1092
to
MP1097
Circular feed rates in the disk cycle
(if marker M2640 is set)
Entry range: 0 to 30 000 [mm/min]
MP1092
Modes: 0 and 4 (erosion, M2640=0)
MP1093
Modes: 0 and 4 (spark-out, M2640=1)
MP1094
Modes: 1 and 5 (erosion, M2640=0)
MP1095
Modes: 1 and 5 (spark-out, M2640=1)
MP1096
Modes: 2/3 and 6/7 (erosion, M2640=0)
MP1097
Modes: 2/3 and 6/7 (spark-out, M2640=1)
Set
Reset
M2616
Free run during erosion or spark-out is completed
PLC
PLC
M2640
Selects the circular feed rate in the disk cycle
PLC
PLC
M2783
End of eroding path reached (WTG = 0)
NC
NC
M2787
Disk erosion in the last circle
NC
NC
M2620
Feed rate from MP2060 becomes active
PLC
PLC
M2790
Disk erosion completed (MOD 0 to 3)
NC
PLC
M2791
Disk erosion completed (MOD 4 to 7)
NC
PLC
W394
Actual angle while disk cycle
NC
NC
6.8 User-parameters
With the MOD-function up to 16 different machine parameters can be made accessible to the
machine operator as User-parameters.
The machine manufacturer determines in machine parameter MP7330.x which machine parameters
are to be defined as User-parameters.
The dialogs for the user-parameters are defined in the PLC dialogs.
MP7330
Determination of user parameters accessible via MOD function
Entry range: 0 to 9999.00 (No. of the desired machine parameter).
MP7330.0
User-parameter 0
MP7330.1
User-parameter 1
.
.
.
.
MP7330.14
User-parameter 14
MP7330.15