beautypg.com

HEIDENHAIN TNC 306 Technical Manual User Manual

Page 282

background image


3/2000

TNC416/TNC 406/TNC 306

List of Markers

6–5

Marker

Function

Set

Reset

Page

M2516

Jog positioning axis Z+

PLC

PLC

4-122

M2517

Jog positioning axis Z–

PLC

PLC

4-122

M2518

Jog positioning axis 4+

PLC

PLC

4-122

M2519

Jog positioning axis 4–

PLC

PLC

4-122

M2520

Jog positioning axis 5+

PLC

PLC

4-122

M2521

Jog positioning axis 5–

PLC

PLC

4-122

M2544

Open control loop axis X

PLC

PLC

4-53

M2545

Open control loop axis Y

PLC

PLC

4-53

M2546

Open control loop axis Z

PLC

PLC

4-53

M2547

Open control loop axis 4

PLC

PLC

4-53

M2548

Reset of accumulated distance for lubrication axis X

PLC

PLC

4-17

M2549

Reset of accumulated distance for lubrication axis Y

PLC

PLC

4-17

M2550

Reset of accumulated distance for lubrication axis Z

PLC

PLC

4-17

M2551

Reset of accumulated distance for lubrication axis 4

PLC

PLC

4-17

M2552

Actual-nominal value transfer axis X
(M2552ff:
effective in all operating modes;
the servo lag is set to 0 for an axis that has been taken out
of the control loop;
monitoring the limit switches is active)

PLC

PLC

4-53

M2553

Actual-nominal value transfer axis Y

PLC

PLC

4-53

M2554

Actual-nominal value transfer axis Z

PLC

PLC

4-53

M2555

Actual-nominal value transfer axis 4

PLC

PLC

4-53

M2556

Reference end position for axis X

PLC

PLC

4-34

M2557

Reference end position for axis Y

PLC

PLC

4-34

M2558

Reference end position for axis Z

PLC

PLC

4-34

M2559

Reference end position for axis 4

PLC

PLC

4-34

M2560

Reference end position for axis 5

PLC

PLC

4-34

M2564

Actual-nominal value transfer axis 5

PLC

PLC

4-53

M2568

Await open control loop axis 5

PLC

PLC

4-53

M2572

Open control loop axis 5

PLC

PLC

4-53

M2576

Reset of accumulated distance for lubrication axis 5

PLC

PLC

4-17

M2609

Status display M08 inverse

PLC

PLC

4-83

M2611

Acknowledgment FN19

PLC

PLC

M2616

Free run during erosion or spark out is completed

PLC

PLC

4-61

M2617

Retraction until signal is reset / Probing stop in TOUCH
PROBE MANUAL

PLC

PLC

4-60
4-114

M2618

Switch-on gap control (0=M37, 1=M36)

PLC

PLC

4-96

M2619

Complement switch on gap control (0=M36,1=M37)

PLC

PLC

4-96

M2620

Retraction feed rate from MP2060 during erosion

PLC

PLC

4-88