beautypg.com

HEIDENHAIN TNC 306 Technical Manual User Manual

Page 194

background image


4-94

TNC 406/TNC 306

7 M-functions

2/97

Evaluation of the M-function must be programmed in the PLC. When transferring an M-function to
the PLC the code for the M-function is stored in Word W260 and the strobe-marker M2045 is set.

The execution of the M-function must be signaled to the NC by setting the markers M2482. The
next NC-block is only processed when the signal is acknowledged and the marker M2045 (strobe
signal for M-function) is reset by the NC.

Marker

Function Set

Reset

M2045

Strobe signal for M-function

NC

NC

M2482

Acknowledgment of M-functionPLC

NC

W260

Code for M-function (NC

→ PLC)

This manual is related to the following products: