beautypg.com

12 memory test, 13 new program start/end of program run, 14 restore position – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 190

background image


4-90

TNC 406/TNC 306

6 Display and operation 4

3/97

6.12 Memory test

A machine parameter can be used to select if the RAM and the EPROM memory areas should be
tested upon switching on the control.

MP7690

Memory test at switch-on
Entry: 0 to 3
Bit 0 RAM-test

+ 0 = Memory test at switch-on
+ 1 = No memory test at switch-on

Bit 1 EPROM-test

+ 0 = Memory test at switch-on
+ 2 = No memory test at switch-on

6.13 New program start/End of program run

If a new program is started, marker M2060 is set.
If the end of the program is reached in operating modes "Program run/single block" or "Program
run/full sequence", the NC sets marker M2061. This marker is only reset at the start of the next
program.
The information "End of program" can be evaluated by the PLC. This is necessary when operating,
for instance, with a pallet-changer.

Set

Reset

M2060

A new program is started

NC

PLC

M2061

END PGM, M02 or M30 has been executed

NC

NC

6.14 Restore position

The reapproach function can be started with the following key sequence:
TEST, PGM-NR, NR, ENT, UP TO, BLOCK NUMBER, ENT, PROGRAM RUN, NC START.
During the Test Run mode marker M2059 is set by the NC. If the TNC is then switched to Program
Run mode (full sequence or single block), marker M2059 is reset by the NC.
If the reapproach is now activated with NC-START, marker M2019 is set by the NC. The marker is
reset by the NC, when the reapproach position is reached.

Set

Reset

M2019

Reapproach activated with NC-START

NC

NC

M2059

TNC in Test Run mode

NC

NC

This manual is related to the following products: