HEIDENHAIN TNC 306 Technical Manual User Manual
Page 226

4-126
TNC 406/TNC 306
13 Datum correction
2/97
PLC example:
Datum correction in Z axis with M20 activated, with M21 deactivated
.
.
L
W260
==
K+20
;M20 activated
A
M2045
S
M10
;buffered marker for strobe marker 2716
CMT 200
;datum correction call
R
M10
L
W260
==
K+21
;M21 activated
A
M2045
S
M10
;buffered marker for strobe marker 2716
CMT 201
;deactivate datum correction call
R
M10
EM
;end of main program
LBL 200
;activate module for datum correction
L
D896
;value from MP4210.32
=
D536
...
;for the other axis the correction value 0 must be entered
...
L
M10
S
M2716
EM
LBL 201
;deactivate module for datum correction
L
D900
;value from MP4210.33
=
D536
L
M10
S
M2716
EM
.
.