HEIDENHAIN TNC 306 Technical Manual User Manual
Page 165

3/97
TNC 406/TNC 306
4 Gap control
4-65
SENS Element servo sensitivity (used directly by the TNC)
LAST Last element on-line
Q154 Element of min-nr. = Q154
Q155 Element of min-nr. = Q155, element of max-nr. = Q156
Q201 Elements transferred to Q201 ... Q225 from min to max
Q231 Elements transferred to Q231 ... Q255 from min to max
Type of number
Integer (I)
I1-9999 1...9999 W
I1-2000
1...2000 W
I1-255
1...255 B
I1-150
1...150 B
I1-99
1...99 B
I1-31
1...31 B
I1-25
1...25 B
I1-20
1...20 B
I1-15
1...15 B
I1-9
1...9 B
I1-3
1...3 B
Integer (I)
I9999
0...9999 W
I999
0...999 W
I255
0...255 B
I180
0...180 B
I150
0...150 B
I120
0...120 B
I100
0...100 B
I99
0...99 B
I90
0...90 B
I60
0...60 B
I31
0...31 B
I30
0...30 B
I25
0...25 B
I21
0...21 B
I20
0...20 B
I15
0...15 B
I9
0...9 B
I3
0...3 B
I2
0/1/2 B
I1
0/1 B
Real (R)
R1D200 0.0 ... 200.0 W
R1D200I W
R1D99 0.0 ... 99.0 W
R1D99I W
R3D9999 0.000 ... 9999.999 D
R3D9999I
R3D1000 0.000 ... 1000.000 D
R3D1000I
R3D999 0.000 ... 999.999 D
R3D999I
R3D9 0.000 ... 9.999 W
R3D9I
R3D1 0.000 ... 1.000 W
R3D1I
(The identifier I means that the
values are converted to inch if
the table is switched to INCH.)
Conditions for table structure:
• The maximum number of elements in the eroding table is 32
• The first two elements must be of the "byte" type
• The first element must be the power stage number
• Word or long elements must start at an even address
• The total number of bytes must be even
• The names of the elements determine the length of the element and must be equal or longer
than the cursor length (fill with space)
• The cursor length is specified by the type of number