4-110
TNC 406/TNC 306
8 Key simulation
2/97
8.2 Machine control panel
A manufacturer's specific machine control panel can be connected to the HEIDENHAIN contouring
controls. See "Mounting and Electrical Installation."
There are 24 PLC inputs (I128 to I151) and 8 PLC outputs (O 0 to O 7) available on the female
connector X27 for the evaluation of the keys on the machine control panel. The evaluation of the
signals from the machine control panel must be performed in the PLC-program. The appropriate
markers will be set thereby. For safety reasons a complement-marker must be reset when some
functions are activated. If the complement-marker is not properly set or reset, the flashing error
message "Error in PLC-program" will appear. The displayed code identifies the marker where the
error has occurred.
An axis-direction key which has been pressed can be stored by marker M2450 (Complement-marker
M2466) . This means that the axis will be traversed until the marker M2450 is reset. This memory
function must be activated by machine parameter MP7680 Bit 9.
MP7680
Memory function for axis-direction keys
0 = Not stored
1 = Stored
Marker
Function
Error
message
Set
Reset
M2448
NC-start (edge evaluation)
1A
PLC
PLC
M2464
Complement NC-start
M2449
Rapid traverse
1B
M2465
Complement – rapid traverse
M2488
NC-stop ("0" signifies stop)
M2450
Memory function for axis-direction keys
1C
M2466
Complement – memory function for axis-
direction keys
M2451
Feed enable
1D
M2467
Complement – feed enable
M2456
Manual traverse X+
1I
M2472
Complement – manual traverse X+
M2457
Manual traverse X–
1J
M2473
Complement – manual traverse X–
M2458
Manual traverse Y+
1K
M2474
Complement – manual traverse Y+
M2459
Manual traverse Y–
1L
M2475
Complement – manual traverse Y–