beautypg.com

Machine control panel, 2 machine control panel – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 210

background image


4-110

TNC 406/TNC 306

8 Key simulation

2/97

8.2 Machine control panel

A manufacturer's specific machine control panel can be connected to the HEIDENHAIN contouring
controls. See "Mounting and Electrical Installation."

There are 24 PLC inputs (I128 to I151) and 8 PLC outputs (O 0 to O 7) available on the female
connector X27 for the evaluation of the keys on the machine control panel. The evaluation of the
signals from the machine control panel must be performed in the PLC-program. The appropriate
markers will be set thereby. For safety reasons a complement-marker must be reset when some
functions are activated. If the complement-marker is not properly set or reset, the flashing error
message "Error in PLC-program" will appear. The displayed code identifies the marker where the
error has occurred.

An axis-direction key which has been pressed can be stored by marker M2450 (Complement-marker
M2466) . This means that the axis will be traversed until the marker M2450 is reset. This memory
function must be activated by machine parameter MP7680 Bit 9.

MP7680

Memory function for axis-direction keys
0 = Not stored
1 = Stored

Marker

Function

Error
message

Set

Reset

M2448

NC-start (edge evaluation)

1A

PLC

PLC

M2464

Complement NC-start

M2449

Rapid traverse

1B

M2465

Complement – rapid traverse

M2488

NC-stop ("0" signifies stop)

M2450

Memory function for axis-direction keys

1C

M2466

Complement – memory function for axis-
direction keys

M2451

Feed enable

1D

M2467

Complement – feed enable

M2456

Manual traverse X+

1I

M2472

Complement – manual traverse X+

M2457

Manual traverse X–

1J

M2473

Complement – manual traverse X–

M2458

Manual traverse Y+

1K

M2474

Complement – manual traverse Y+

M2459

Manual traverse Y–

1L

M2475

Complement – manual traverse Y–

This manual is related to the following products: