To do…

Use the command…

Remarks

Configure the source IP address of
a probe request in a test operation

source ip ip-address

Optional
By default, no source IP address is
specified.
The source IP address must be
that of an interface on the device
and the interface must be up.
Otherwise, the test will fail.

Configure common optional
parameters

Refer to

Configuring Optional

Parameters Common to an NQA
Test Group

Optional

Configuring the TCP Test

You are not recommended to perform an NQA TCP test on ports from 1 to 1023 (known ports).
Otherwise, the NQA test will fail or the corresponding services of this port will be unavailable.

The TCP test is used to test the TCP connection between the client and the specified server and the
setup time for the connection.

Configuration prerequisites

A TCP test requires cooperation between the NQA server and the NQA client. The TCP listening
function needs to be configured on the NQA server before the TCP test.

Configuring the TCP test

Follow these steps to configure the TCP test:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter NQA test group view

nqa

entry admin-name

operation-tag

Configure the test type as TCP and
enter test type view

type

tcp Required

Configure the destination address
for a test operation

destination ip

ip-address

Required
By default, no destination IP
address is configured for a test
operation.
The destination address must be
the IP address of the listening
service configured on the NQA
server.