Understanding Feedback
and I/O Cable Connections

Factory made cables with premolded connectors are designed to minimize
EMI and are recommended over hand-built cables to improve system
performance. However, other options may be available for building your own
feedback and I/O cables. Refer to the table below for the available options.

Drive Connector

Connector Option

Option Catalog
Number

Reference

CN1

I/O Connector

CN1 Control Cable, premolded cable with 50-pin connector to
drive, flying leads to controller

2090-DAIO-D50xx

1

Understanding Ultra1500 I/O

Specifications beginning on page
2-5.

CN1 mini-D Connector Kit (50 pin solder cup type)

9101-1476

CN2

Feedback Connector

CN2 Feedback Cable for TL-Series Motors, premolded cable with
motor connector, and 20-pin connector at drive end.

2090-DANFCT-Sxx

1

Understanding Ultra1500 Motor

Encoder Feedback Specifications
beginning on page 2-14.

CN2 mini-D Connector Kit (20 pin solder cup type)

9101-1477

CN3

Serial Connector

PC Cable, premolded cable with connectors both ends

2090-DAPC-D09xx

1

Understanding the Ultra1500 Serial

Interface beginning on page 2-23.

CN2 mini-D Connector Kit (20 pin solder cup type)

9101-1477