Position regulator, Position regulator -40, Figure 5.20 position regulator block diagram – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 120
Publication 2092-UM001D-EN-P — July 2005
5-40
Ultra1500 Application Examples
Position Regulator
Figure 5.20 shows the block diagram of the position regulator in the Ultra1500
Figure 5.20
Position Regulator Block Diagram
The Ultra1500 uses a fixed frequency (5 kHz) to sample data and perform
computations (i.e., the sample or update rate is 200 µs). A z
-1
block in the
figure indicates a delay of one update period, or 200 µs. This implies that any
signal multiplied by a z
-1
block will use the signal from the previous update in
the calculation for the current update.
z
-1
-
+
z
-1
+
K
gear
K
gear
+
-
K
ff
+Offset
-Offset
0.0
K
'
p
+
+
+
+
1
Sampled
Master
Position
Command
Sampled
Follower
(Motor)
Position
Feedback
2
3
4
7
5
1
2
3
Block/Switch Definitions:
1
Mode Configuration : Follower : Gear Ratio
2
Tuning Window : Main Position Regulator Gains : K
ff
3
Tuning Window : Main Position Regulator Gains : K
ff
Low Pass Filter Bandwidth
4
Tuning Window : Main Position Regulator Gains : K
p
5
Tuning Window : Main Position Regulator Gains : High Error Output Threshold
6
Tuning Window : Main Position Regulator Gains : High Error Output Offset
7
Velocity command limt to motor rated speed
4
6
Signal Definitions:
1
Delta position command (velocity command): master counts
2
Velocity command: follower counts
3
Delta position : follower counts. Fractional counts are managed here for a lossless conversion.
4
Position command : follower counts
5
Position Error : follower counts
5
Velocity
Command
To Velocity
Regulator
1
Block/Switch definitions shown in Figure 5.20 refer to the Ultraware parameter names where applicable.