beautypg.com

Position regulator, Position regulator -40, Figure 5.20 position regulator block diagram – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 120

background image

Publication 2092-UM001D-EN-P — July 2005

5-40

Ultra1500 Application Examples

Position Regulator

Figure 5.20 shows the block diagram of the position regulator in the Ultra1500

Figure 5.20
Position Regulator Block Diagram

The Ultra1500 uses a fixed frequency (5 kHz) to sample data and perform
computations (i.e., the sample or update rate is 200 µs). A z

-1

block in the

figure indicates a delay of one update period, or 200 µs. This implies that any
signal multiplied by a z

-1

block will use the signal from the previous update in

the calculation for the current update.

z

-1

-

+

z

-1

+

K

gear

K

gear

+

-

K

ff

+Offset

-Offset

0.0

K

'

p

+

+

+

+

1

Sampled

Master

Position

Command

Sampled

Follower

(Motor)

Position

Feedback

2

3

4

7

5

1

2

3

Block/Switch Definitions:

1

Mode Configuration : Follower : Gear Ratio

2

Tuning Window : Main Position Regulator Gains : K

ff

3

Tuning Window : Main Position Regulator Gains : K

ff

Low Pass Filter Bandwidth

4

Tuning Window : Main Position Regulator Gains : K

p

5

Tuning Window : Main Position Regulator Gains : High Error Output Threshold

6

Tuning Window : Main Position Regulator Gains : High Error Output Offset

7

Velocity command limt to motor rated speed

4

6

Signal Definitions:

1

Delta position command (velocity command): master counts

2

Velocity command: follower counts

3

Delta position : follower counts. Fractional counts are managed here for a lossless conversion.

4

Position command : follower counts

5

Position Error : follower counts

5

Velocity

Command

To Velocity

Regulator

1

Block/Switch definitions shown in Figure 5.20 refer to the Ultraware parameter names where applicable.