Publication 2092-UM001D-EN-P — July 2005

D-6

Ultra1500 Operator Interface

This table defines only those variables that can be selected for the
following parameters:

Pr-5.12 Analog Output 1: Signal on page D-28,

Pr-5.13 Analog Output 2: Signal on page D-28,

Pr-6.07 Fault Detail Setup: Channel A on page D-30

Pr-6.08 Fault Detail Setup: Channel B on page D-30,

Pr-6.09 Fault Detail Setup: Channel C on page D-30, and

Pr-6.10 Fault Detail Setup: Channel D on page D-31.

16

Error History

Up to eight alarms stored in numerical order (most
recent =1, to oldest =8) with error code number:

Most significant digit is alarm number (1–8),
Least significant six digits are the error code number
referenced in the Error Displays beginning on page 6-5.
e.g., 1-E004 = most recent error is a Motor Overtemp

17

Firmware Version

e.g., vErx.yy where x = version, yy = revision

18

Motor Temperature

%

19

Instantaneous Output
Power

Watts

20

Output Power Limit
Ratio

%

Variable
Numbers

Name

Unit

00

Velocity Feedback

rpm or mm/sec

01

Velocity Command

rpm or mm/sec

02

Velocity Error

rpm or mm/sec

03

Current Command

0.1% of motor rated continuous torque

04

Follower Position

counts

05

Master Position

counts

06

Position Error

counts

07

Position Command
Count Frequency

0.1 kilocounts/sec

08

Commutation Angle

0.1

o

(degrees)

09

Mechanical Angle

0.1

o

(degrees)

10

Shunt Power Limit Ratio

%

11

Bus Voltage

V

12

Absolute Rotations

revolutions

13

Velocity Command
Offset

mV

14

Current Command Offset mV

Variable
Numbers

Name

Unit