beautypg.com

Group 2 parameters – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 183

background image

Publication 2092-UM001D-EN-P — July 2005

Ultra1500 Operator Interface

D-19

Group 2 Parameters

Group 2 Parameters provide speed control settings.

Pr-2.00 Analog Velocity Command Scale

Pr-2.01 Jog Velocity Command

Pr-2.02 Acceleration Limits: Acceleration

Pr-2.03 Acceleration Limits: Deceleration

Pr-2.04 Acceleration Limits: S-Curve Time

Range:

100 to 20000

Default:

5000

Units:

rpm/V*10 for rotary motors

mm/sec/V*10 for linear motors

Applicable Operating Mode:

Analog Velocity

Range:

0 to 5000

Default:

500

Units:

rpm for rotary motors

mm/sec for linear motors

Applicable Operating Mode:

All

Range:

0 to 60000

Default:

0

Units:

msec

Applicable Operating Mode:

Analog Velocity, Preset Velocity, Follower

Ultraware Link:

Acceleration Limits: Acceleration

Range:

0 to 60000

Default:

0

Units:

msec

Applicable Operating Mode:

Analog Velocity, Preset Velocity, Follower

Ultraware Link:

Acceleration Limits: Deceleration

Range:

0 to 5000

Default:

0

Units:

msec

Applicable Operating Mode:

Analog Velocity, Preset Velocity, Follower

Ultraware Link:

Acceleration Limits: S-Curve Time