Ultra1500 Operator Interface

D-25

Pr-4.06 Initial Current Bias

Group 5 Parameters

Group 5 Parameters provide supplementary drive system and I/O settings

Pr-5.00 Position Functions: In Position Size

Pr-5.01 Position Functions: Near Position Size

Pr-5.02 Speed Functions: Speed Window

Ultraware Link:

Initial Current Bias

Description:

Prevents the downturn of vertical load during initial operation

Range:

-100 to100

Default:

0

Units:

% of motor rated continuous current

Applicable Operating Mode:

All

Description:

If the position error is within the limit set in In Position Size
and a digital output is defined as In Position, then the digital
output is turned ON.

Range:

0 to 2500

Default:

10

Units:

Counts

Applicable Operating Mode:

Follower

Ultraware Link:

Position Functions: In Position Size

Description:

If the position error is within the limit set in Near Position Size
and a digital output is defined as Near Position, then the
digital output is turned ON.

Range:

0 to 2500

Default:

20

Units:

Counts

Applicable Operating Mode:

Follower

Ultraware Link:

Position Functions: Near Position Size

Description:

If the speed error is within the limit set in Speed Window and
a digital output is defined as Within Speed Window, then the
digital output is turned ON.

Range:

0 to 1000

Default:

10

Units:

rpm for rotary motors