D-25
Pr-4.06 Initial Current Bias
Group 5 Parameters
Group 5 Parameters provide supplementary drive system and I/O settings
Pr-5.00 Position Functions: In Position Size
Pr-5.01 Position Functions: Near Position Size
Pr-5.02 Speed Functions: Speed Window
Ultraware Link:
Initial Current Bias
Description:
Prevents the downturn of vertical load during initial operation
Range:
-100 to100
Default:
0
Units:
% of motor rated continuous current
Applicable Operating Mode:
All
Description:
If the position error is within the limit set in In Position Size
and a digital output is defined as In Position, then the digital
output is turned ON.
Range:
0 to 2500
Default:
10
Units:
Counts
Applicable Operating Mode:
Follower
Ultraware Link:
Position Functions: In Position Size
Description:
If the position error is within the limit set in Near Position Size
and a digital output is defined as Near Position, then the
digital output is turned ON.
Range:
0 to 2500
Default:
20
Units:
Counts
Applicable Operating Mode:
Follower
Ultraware Link:
Position Functions: Near Position Size
Description:
If the speed error is within the limit set in Speed Window and
a digital output is defined as Within Speed Window, then the
digital output is turned ON.
Range:
0 to 1000
Default:
10
Units:
rpm for rotary motors