beautypg.com

Ultra1500 power specifications, Main input power, Control input power – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 136: Input power connector, N ultra1500 power specifications, Ultra1500 power specifications in

background image

Publication 2092-UM001D-EN-P — July 2005

A-2

Specifications and Dimensions

Ultra1500 Power
Specifications

The following sections provide power specifications for the Ultra1500.

Ultra1500 Power Specifications

The tables below lists general power specifications and requirements for the
Ultra1500 drives (2092-DAx).

Main Input Power

Control Input Power

Input Power Connector

Drives

2092-DA1 2092-DA2 2092-DA3 2092-DA4 2092-DA5

Input Voltage

1

200–240 Vrms, 1

φ

200–240 Vrms, 3

φ

Input Current

2

3.3 Arms

5.5 Arms

8.0 Arms

11.0 Arms

15.0 Arms

Input Frequency

47–63 Hz

Inrush Current

2

200 Apeak, maximum

Power Cycling

0.5 power cycles/minute maximum

Delay before Drive Enable

500ms, minimum (after main power is applied)

1 Specifications are for nominal voltage. The absolute limits are +/-10% (180–265 Vrms).
2 Power initialization requires a short period of inrush current. Dual element time delay (slow blow) fuses are recommended in Fuse and Contactor

Specifications on page A-4.

Input Voltage

1

200–240 Vrms, 1

φ

Input Current

2

2.0 Arms

Input Frequency

47–63 Hz

Inrush Current

2

75 Apeak, maximum

1 Specifications are for nominal voltage. The absolute limits are +/-10% (180–265 Vrms).
2 Power initialization requires a short period of inrush current. Dual element time delay (slow blow) fuses are

recommended in Fuse and Contactor Specifications on page A-4.

Description

Pluggable cage-clamp, 7.5mm spacing

Manufacturer

Wago 231-206/026-000

Acceptable Wire Gauge

2.5–0.5 mm

2

(14–20 AWG)

Operating Tool

Wago 231-131

Pinout