Publication 2092-UM001D-EN-P — July 2005

D-16

Ultra1500 Operator Interface

Pr-1.02 Main Velocity Regulator Gains: Integrator Time

Pr-1.03 Main Position Regulator Gains: Kp

Pr-1.04 Main Current Regulator Gains: Lowpass Filter Bandwidth

Pr-1.05 Main Velocity Regulator Gains: Low Pass Filter Bandwidth

Pr-1.06 Reserved

Pr-1.07 Main Current Regulator Gains: Resonant Frequency
Suppression

Range:

0 to 60000

Default:

26

Applicable Operating Mode:

Follower, Analog Velocity, Preset Velocity

Ultraware Link:

Main Velocity Regulator Gains: Integrator Time

Range:

0 to 700

Default:

20

Units:

Hz

Applicable Operating Mode:

Follower

Ultraware Link:

Main Position Regulator Gains: Kp

Range:

0 to 10000

Default:

300

Units:

Hz

Applicable Operating Mode:

All

Ultraware Link:

Main Current Regulator Gains: Lowpass Filter Bandwidth

Range:

0 to 10000

Default:

1000

Units:

Hz

Applicable Operating Mode:

Follower, Analog Velocity, Preset Velocity

Ultraware Link:

Main Velocity Regulator Gains: Low Pass Filter Bandwidth

This parameter is Reserved.

Description:

Suppresses vibration by cutting off the Current Command in
the assigned frequency band.

Range:

0 to 10000

Default:

10000