beautypg.com

Control power - l1c and l2c, Dc bus negative - n – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 55

background image

Publication 2092-UM001D-EN-P — July 2005

Ultra1500 Connector Data

2-25

Figure 2.25
Timing Requirement s of the Drive Enable Input

Control Power – L1C and L2C

L1C and L2C are the single-phase control power inputs for all Ultra1500
drives. These AC inputs power drive logic and I/O circuitry.

DC Bus Negative – N

N is the negative side of the DC power bus on all 2092 drives.

Note: The positive side (P) of the DC power bus is provided on the DC Bus

and Shunt power connector.

If the 2092 drive is to be powered from a DC source, the DC power supply is
connected to P2 on the DC Bus and Shunt power connector, and N on the
Main Input power connector. The L1, L2, L3, and P1 terminals should be
disconnected.

IMPORTANT

The drive requires 500 ms after the main AC input has
been applied before it can be enabled, as shown in Figure
2.25.

ATTENTION

!

The N terminal (labelled DC- on the removable connector) IS NOT an
Input Power connection.

t

DELAY

= 500mS, minimum

Main AC
Input

DC Bus
Voltage

Drive Enable
(software or
hardware)