Understanding ultra1500 i/o specifications, Digital i/o power supply, Digital inputs – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 35: Understanding ultra1500 i/o specifications -5, Digital i/o power supply -5 digital inputs -5
Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Connector Data
2-5
Understanding Ultra1500 I/O
Specifications
A description of the Ultra1500 input/output is provided starting below.
Digital I/O Power Supply
All Ultra1500 drives require an external 24V power supply for proper
operation of the digital inputs. The following table provides a description of
the digital I/O power supply.
Note: A single 24V power supply can be used to power the digital I/O on
multiple drives, provided the cumulative minimum current requirements
are met.
Digital Inputs
There are seven opto-isolated digital inputs. Any input can be configured for
one of the following functions using Ultraware software: Drive Enable,
Positive Overtravel, Negative Overtravel, Positive Current Limit, Negative
Current Limit, Fault Reset, Integrator Inhibit, Operation Mode Override, Zero
Speed Clamp Enable, Reset Multiturn Data, Preset Selects, Preset Direction,
Alternate Gain Select, Position Strobe, and Pause Follower.
Digital inputs are active low, current sourcing. All have the same configuration,
as shown in Figure 2.2.
Figure 2.2
Digital Input Circuit
Parameter
Description
Minimum
Maximum
I/O Power Supply
Voltage
Voltage range of the external power supply for
proper operation of the digital I/O.
21.6V
26.4V
I/O Power Supply
Current
Current draw per drive from the external power
supply for the digital inputs.
—
64 mA
+5V
INPUTS
4.7k
Ω
Logic Grnd
PS2801
330
Ω
0.01
µF
3.3k
Ω
+24V IN
Ultra1500
Drive