beautypg.com

Understanding ultra1500 i/o specifications, Digital i/o power supply, Digital inputs – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 35: Understanding ultra1500 i/o specifications -5, Digital i/o power supply -5 digital inputs -5

background image

Publication 2092-UM001D-EN-P — July 2005

Ultra1500 Connector Data

2-5

Understanding Ultra1500 I/O
Specifications

A description of the Ultra1500 input/output is provided starting below.

Digital I/O Power Supply

All Ultra1500 drives require an external 24V power supply for proper
operation of the digital inputs. The following table provides a description of
the digital I/O power supply.

Note: A single 24V power supply can be used to power the digital I/O on

multiple drives, provided the cumulative minimum current requirements
are met.

Digital Inputs

There are seven opto-isolated digital inputs. Any input can be configured for
one of the following functions using Ultraware software: Drive Enable,
Positive Overtravel, Negative Overtravel, Positive Current Limit, Negative
Current Limit, Fault Reset, Integrator Inhibit, Operation Mode Override, Zero
Speed Clamp Enable, Reset Multiturn Data, Preset Selects, Preset Direction,
Alternate Gain Select, Position Strobe, and Pause Follower.

Digital inputs are active low, current sourcing. All have the same configuration,
as shown in Figure 2.2.

Figure 2.2
Digital Input Circuit

Parameter

Description

Minimum

Maximum

I/O Power Supply
Voltage

Voltage range of the external power supply for
proper operation of the digital I/O.

21.6V

26.4V

I/O Power Supply
Current

Current draw per drive from the external power
supply for the digital inputs.

64 mA

+5V

INPUTS

4.7k

Logic Grnd

PS2801

330

0.01

µF

3.3k

+24V IN

Ultra1500