Connecting motor power, Wiring motor power, Connecting motor power -12 – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 70: Wiring motor power -12, Figure 3.9)
Publication 2092-UM001D-EN-P — July 2005
3-12
Connecting Your Ultra1500
Figure 3.9
Using the Power Connector Tool
5. Tighten the ground terminal screw. to 1.25 Nm (11 lbs-in.).
6. Gently pull on each wire to make sure it does not come out of its terminal.
Re-insert any loose wires.
7. Re-insert the Input Power connector on the terminal block. The
connector is keyed to prevent incorrect installation.
Connecting Motor Power
This procedure assumes you have wired your input power and are ready to
wire the motor power connections.
Refer to Figure 3.8 for the power wiring diagram for your Ultra1500.
Wiring Motor Power
When using TL-Series motors refer to Figure 3.10 for your motor power cable
configuration.
IMPORTANT
The DC bus connections should not be used for
connecting multiple drives together. Contact your
Allen-Bradley representative for further assistance if the
application may require DC power connections.
1
2
1. Open terminal locking clamp with connector tool as shown.
2. Insert wire, and then release tool.
3. Gently pull on the wire to make sure it is secure.
IMPORTANT
Torque the ground screws securing the wires to 1.25 Nm
(11 lbs-in.).
IMPORTANT
To ensure system performance, run wires and cables in the
wireways as established in Chapter 1.