beautypg.com

Position command inputs, Position command inputs -12 – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 42

background image

Publication 2092-UM001D-EN-P — July 2005

2-12

Ultra1500 Connector Data

Position Command Inputs

The Ultra1500, when operating in follower mode, accepts position command
signals from a controller.

Position command inputs can be A quad B, Step/Direction, or Step Up/
Step Down format as shown in Figure 2.8.

Figure 2.8
Position Command Input Signal Types

Figure 2.9 shows the configuration of the Position Command inputs, and the
following table provides descriptions of these inputs.

Figure 2.9
Position Command Interface Example

Parameter

Description Minimum

Maximum

ON State Input
Voltage

Input voltage difference between the + input
and the - input that is detected as an ON
state.

2.8V

3.7V

STEP (CN1-11 and -12)

DIRECTION (CN1-13 and -14)

STEP UP (CN1-11 and -12)

STEP DOWN (CN1-13 and -14)

A (CN1-11 and -12)

B (CN1-13 and -14)

+5V

AX-

680

Logic Ground

M456

1 k

0.001

µF

150

AX+

Ultra1500
Drive