Low Voltage Directive

These units are tested to meet Council Directive 73/23/EEC Low Voltage
Directive. The standard EN 50178 Electronic Equipment for use in Power
Installations
applies in whole or in part.

Refer to Appendix B for interconnect information.

Meeting Emission Requirements

To meet emission requirements the following components are required:

• Install an AC line filter (2090-UXLF-xxx or -HVxxx) between the AC

power source and the drive input, and as close to the drive as possible
(refer to Appendix C for available AC line filters).

• Connect both Main and Control input power to the load side of the AC

line filter for the drive.

• Use 2090 series motor power and feedback cables and terminate the

power cable shields to the drive chassis and motor/machine frame.

• Install the Ultra1500 system inside an enclosure (grounded to the

enclosure), and run input power wiring in conduit outside of the
enclosure.

• Separate signal and power cables as shown in Planning Your Panel Layout of

this chapter.

• Install ferrites on the AC input power cable, and motor (output) power

cable, and motor feedback cable nearest the drive. Steward 28A2024-QAO
has demonstrated compliance on the motor feedback cable, and Steward
28R2024-ORO has been qualified with the power cables.