beautypg.com

Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 133

background image

Publication 2092-UM001D-EN-P — July 2005

Maintaining and Troubleshooting Your Ultra1500

6-7

E036
Drive Overtemperature

Excessive heat exists in the drive

• Verify cooling fan operation (2092-DA4 and

2092-DA5 only).

• Check tuning.

• Reduce acceleration rate.

• Reduce duty cycle (ON/OFF) of commanded

motion.

• Increase time permitted for motion.

• Use larger drive and motor.

E037
AC Line Loss

Poor quality power

Increase Ride Through time.

Attempted to enable drive without main
power active

Apply main power before enabling drive.

Phase connection missing

Remove power and verify all physical connections.

Fault Delay parameter is set too short

Increase the Fault Delay parameter setting.

E053
User Parameter
Initialization Error

Error in parameter memory storage

• Reinitialize parameter.

• Reset drive to factory defaults.

E054
Current Feedback Offset

Defective hardware

Replace drive.

E055
User Parameter
Checksum Error

Checksum error

• Confirm and reset parameter.

• Reset drive to factory defaults.

E056
Watchdog Timeout

Excessive system noise

Verify wiring and installation methods.

Defective hardware

Replace drive.

E057

PWM Hardware Error

Defective hardware

Contact A-B.

E058
User Parameter Range
Error

Range of parameter is invalid

• Enter parameter with value(s) within range.

• Reset drive to factory defaults.

E060
Drive Initialization Error

Hardware error

Replace drive.

E075
Shunt Overload
Protection

Power at regenerative resistor exceeds
the permitted value

Adjust motion profile to stay within the range of the
regenerative resistor.

Shunt resistor is disconnected or
damaged

• Verify resistor connection.

• Verify resistance of shunt resistor.

E079
Shunt Overcurrent
Protection

Shunt current exceeded allowable
instantaneous value

• Verify shunt is not shorted or damaged.

• Verify load energy is not excessive during

deceleration.

E083
Absolute Encoder Battery
Error

Encoder Backup Battery parameter is set
to installed, but a battery is not installed.

Set Encoder Backup Battery parameter to Not
Installed.

Battery voltage is sensed below 2.7V dc.

• Confirm battery voltage and connection.

• Replace battery.

E084
Absolute Encoder
Overspeed

Battery powered encoder is mechanically
rotated at high speed while drive is
powered down

• Mechanically disengage motor from system.

• Cycle power to drive and reset alarm.

E085
Absolute Encoder
Multi-turn Count Error

Noise in the encoder

Cycle power to drive and reset alarm.

Defective encoder

Replace motor.

E086
Encoder Single-Turn
Count Error

Noise in the encoder

Cycle power to drive and reset alarm.

Defective encoder

Replace motor.

Error Display

Description

Possible Cause(s)

Action/Solution

Code

Text