Power connections – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 146
![background image](/manuals/580233/146/background.png)
Publication 2092-UM001D-EN-P — July 2005
B-2
Interconnect and Cable Diagrams
Power Connections
Figure B.1 shows the recommended power wiring for a typical Ultra1500 drive
and motor system.
Figure B.1
Ultra1500 Simplifier Power Wiring Diagram
L1
ULTRA1500
L2
L3
L1C
L2C
N
P1
P2
B1
B2
M1
AC
LINE
FILTER
SHUNT
RESISTOR
U
V
W
MOTOR
FUSE
BLOCK
1:1 ISOLATION
TRANSFORMER
GROUND BAR
1
1
2
3
4
4
FUSED
DISCONNECT
OR CIRCUIT
BREAKER
230V
3-PHASE
AC LINE
50/60 HZ
TO
ADDITIONAL
DRIVES
NOTES:
1.
HIGH-FREQUENCY GROUNDING USING HEAVY BRAIDS SHOULD CONNECT TOGETHER THE ELECTRONIC EQUIPMENT, THE ELECTRICAL ENCLOSURE, THE
MACHINE FRAME AND THE MOTOR HOUSING.
2.
THE INTERNAL SHUNT RESISTOR IS ONLY PRESENT ON THE 2092-DA3, 2092-DA4, AND 2092-DA5 MODELS. B1 AND B2 SHOULD BE LEFT DISCONNECTED ON
THE 2092-DA1 AND 2092-DA2 MODELS.
3.
AN ISOLATION TRANSFORMER IS OPTIONAL. IF USED, THE SECONDARY OF THE TRANSFORMER MUST BE GROUNDED.
4.
THE 2092-DA1 AND 2092-DA2 MODELS HAVE ONE GROUNDING SCREW ON THE HEATSINK, AND THE 2092-DA3, 2092-DA4, AND 2092-DA5 MODELS HAVE TWO
GROUNDING SCREWS ON THE HEATSINK.
5.
THE 2092-DA1, 2092-DA2, AND 2092-DA3 MODELS ARE SINGLE-PHASE AC INPUT, AND L3 SHOULD BE LEFT DISCONNECTED.
6.
THE JUMPER FROM P1 TO P2 CAN BE REPLACED WITH AN INDUCTOR, IF THE POWER FACTOR OR HARMONIC DISTORTION NEEDS IMPROVEMENT.
5
CASE
6