Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 167
Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Operator Interface
D-3
2. Select the function to perform from the list below using either the UP or
DOWN key: Select from: 00 the Jog function, 01 the Run Auto Tuning
function, through 12 the Reset to Factory Settings function.
Functions 02, 07, 09, and 13 display, but are Reserved functions.
3. Press the ENTER key to load the function. An abbreviated text message
indicates the function to be performed.
For example, Function 00 displays the text message -JoG-.
Note: Some functions can only be performed if the drive resides in a
particular status.
Function Number
and Command
Abbreviation
Description
Notes
00
-JoG-
Jog
Parameter 2.01 and the Velocity
Control Panel window of
Ultraware store the jog velocity.
01 -AUto-
Run
Auto
Tuning
02
2-PULS
Reserved
Not accessible to user
03
At-SCo
Remove Velocity Input Offset
04
At-CCo
Remove Current Input Offset
05
AJ-SCo
Manually Adjust Velocity Input Offset
Parameter 6.00 and the Analog
window of Ultraware stores
Velocity Input Offset.
06
AJ-CCo
Manually Adjust Current Input Offset
Parameter 6.01 and the Analog
window of Ultraware stores
Current Input Offset.
07
AT-PCo
Reserved
Not accessible to user
08 AL-rST
Fault
Reset
09
AH-CLr
Reserved
Not accessible to user
10
EnCrSt
Absolute Encoder Reset
11
2-GAIn
Copy Main Gains to Alternate
12
Pr-rST
Reset to Factory Settings
13
tStrun
Reserved
Not accessible to user