Ultra1500 Operator Interface

D-3

2. Select the function to perform from the list below using either the UP or

DOWN key: Select from: 00 the Jog function, 01 the Run Auto Tuning
function, through 12 the Reset to Factory Settings function.

Functions 02, 07, 09, and 13 display, but are Reserved functions.

3. Press the ENTER key to load the function. An abbreviated text message

indicates the function to be performed.

For example, Function 00 displays the text message -JoG-.

Note: Some functions can only be performed if the drive resides in a

particular status.

Function Number
and Command
Abbreviation

Description

Notes

00

-JoG-

Jog

Parameter 2.01 and the Velocity
Control Panel window of
Ultraware store the jog velocity.

01 -AUto-

Run

Auto

Tuning

02

2-PULS

Reserved

Not accessible to user

03

At-SCo

Remove Velocity Input Offset

04

At-CCo

Remove Current Input Offset

05

AJ-SCo

Manually Adjust Velocity Input Offset

Parameter 6.00 and the Analog
window of Ultraware stores
Velocity Input Offset.

06

AJ-CCo

Manually Adjust Current Input Offset

Parameter 6.01 and the Analog
window of Ultraware stores
Current Input Offset.

07

AT-PCo

Reserved

Not accessible to user

08 AL-rST

Fault

Reset

09

AH-CLr

Reserved

Not accessible to user

10

EnCrSt

Absolute Encoder Reset

11

2-GAIn

Copy Main Gains to Alternate

12

Pr-rST

Reset to Factory Settings

13

tStrun

Reserved

Not accessible to user