Monitor Mode

The Monitor mode displays numerical data about drive and motor functions.
To access the monitor data:

1. Enter the Monitor mode by pressing the MODE key. The display indicates

the selected Function by displaying

(where nn is a variable number from the tables below).

2. Using either the UP, DOWN, RIGHT, or LEFT keys, select a Variable

Number listed the appropriate table below. Select from: 00 the Velocity
Feedback
variable, 01 the Velocity Command variable, through 20 the
Output Power Limit Ratio variable.

The table on page D-5 defines the variables that can be selected for the
monitor.

3. Press the ENTER key to display the value of the variable.

Variable
Numbers

Name

Unit

00

Velocity Feedback

rpm or mm/sec

01

Velocity Command

rpm or mm/sec

02

Velocity Error

rpm or mm/sec

03

Current Command

0.1% of motor rated continuous torque

04

Follower Position

counts

05

Master Position

counts

06

Position Error

counts

07

Position Command
Count Frequency

0.1 kilocounts/sec

08

Commutation Angle

0.1

o

(degrees)

09

Mechanical Angle

0.1

o

(degrees)

10

Shunt Power Limit Ratio

%

11

Bus Voltage

V

12

Absolute Rotations

revolutions

13

Velocity Command
Offset

mV

14

Current Command Offset mV

15

Input and Output State

Digital Outputs 3 - 1:
3 and 1 active

Servo Alarm:
No errors

E-Stop:
Not active

Digital Inputs 7 - 1:
6, 5, 3, and 1 active

7

1

3

1

2

3

2

5

4

6