Monitor mode – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 169
Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Operator Interface
D-5
Monitor Mode
The Monitor mode displays numerical data about drive and motor functions.
To access the monitor data:
1. Enter the Monitor mode by pressing the MODE key. The display indicates
the selected Function by displaying
(where nn is a variable number from the tables below).
2. Using either the UP, DOWN, RIGHT, or LEFT keys, select a Variable
Number listed the appropriate table below. Select from: 00 the Velocity
Feedback variable, 01 the Velocity Command variable, through 20 the
Output Power Limit Ratio variable.
The table on page D-5 defines the variables that can be selected for the
monitor.
3. Press the ENTER key to display the value of the variable.
Variable
Numbers
Name
Unit
00
Velocity Feedback
rpm or mm/sec
01
Velocity Command
rpm or mm/sec
02
Velocity Error
rpm or mm/sec
03
Current Command
0.1% of motor rated continuous torque
04
Follower Position
counts
05
Master Position
counts
06
Position Error
counts
07
Position Command
Count Frequency
0.1 kilocounts/sec
08
Commutation Angle
0.1
o
(degrees)
09
Mechanical Angle
0.1
o
(degrees)
10
Shunt Power Limit Ratio
%
11
Bus Voltage
V
12
Absolute Rotations
revolutions
13
Velocity Command
Offset
mV
14
Current Command Offset mV
15
Input and Output State
Digital Outputs 3 - 1:
3 and 1 active
Servo Alarm:
No errors
E-Stop:
Not active
Digital Inputs 7 - 1:
6, 5, 3, and 1 active
7
1
3
1
2
3
2
5
4
6