Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 191

Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Operator Interface
D-27
Pr-5.07 Brake Active Delay
Pr-5.08 Stopping Functions: Braking Application Speed
Pr-5.09 Following Error Limit
Pr-5.10 AC Line Loss Fault Delay
Units:
10 msec
Applicable Operating Mode:
All
Ultraware Link:
Stopping Functions: Disable Delay
Description:
Brake Active Delay is the time from when Drive Disable
command is received to when the brake starts operating.
Range:
0 to 1000
Default:
50
Units:
10 msec
Applicable Operating Mode:
All
Ultraware Link:
Brake Active Delay
Description:
Braking Application Speed is the feedback speed, after
disabling the drive, below which the motor brake is engaged.
Range:
0 to 1000
Default:
100
Units:
rpm for rotary motors
mm/sec for linear motors
Applicable Operating Mode:
All
Ultraware Name:
Braking Application Speed
Description:
A Follower Error fault occurs when the difference between
position command and actual position is greater than value
set by the Following Error Limit parameter.
Range:
0 to 99999
Default:
20480
Units:
Counts
Applicable Operating Mode:
Follower
Ultraware Link:
Following Error Limit
Description:
AC Line Loss Fault Delay is the time allowed for power to be
down without triggering of a power down fault.
Range:
20 to 1000
Default:
20
Description:
Disable Delay is the time from when Drive Disable command
is received to when the command is actually executed.
Range:
0 to 1000