beautypg.com

Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 174

background image

Publication 2092-UM001D-EN-P — July 2005

D-10

Ultra1500 Operator Interface

Pr-0.01 Motor and Encoder Selection

Pr-0.02 Basic Motor Operations

Applicable Operating Mode

All

Data Size:

4 digits

Digit 0:

Auto Motor Identification

Range:

Value

Description

0x0

Disable automatic motor
identification

0x1

Enable automatic motor
identification

Default:

1

Digit 1:

Encoder Backup Battery (Single- or Multi-turn Absolute
Encoder)

Range:

Value

Description

0x0

Backup battery installed
(multi-turn)

0x1

Backup battery not installed
(single-turn)

Default:

1

Digit 2:

Incremental Feedback Loss (Encoder Line Break Detection)

Range:

Value

Description

0x0

Enable encoder feedback loss
error checking

0x1

Disable encoder feedback
loss error checking

Default:

0

Digit 3:

Reserved

Default:

0

Applicable Operating Mode

All

Data Size:

4 digits

Digits 0:

Fault and Disable Braking

Range:

Value

Description

0x0

Brake and hold

0x1

Brake and release

0x2

Free stop

0x3

Free stop and hold

Default:

1